Dehumidifier
Model HC70 | Specification Sheet
SPECIFICATIONS
Capacity⁽¹⁾
70ppd
Energy Factor⁽¹⁾
2.1 L/kW-h
Airflow @ varying E.S.P.
(external static pressure – dry coil)
0.0″ w.c.
0.2″ w.c.
0.4″ w.c.
200 CFM
170 CFM
140 CFM
Current Draw⁽¹⁾
5.8 Amps
Noise
53 dBA ducted | 58 dBA unducted
Dimensions: (cabinet only)⁽²⁾
Width
Height
Length
12.5″
12.5″
25.0″
Weight
56 lbs.
Inlet air operating conditions during
-Dehumidification:
50°F – 104°F, 40°F
dew point min.
-Ventilation:
40°F – 140°F,
0% – 99%RH
(non-condensing)
⁽¹⁾ Rated capacity and energy factor test done and current draw measured in accordance with AHAM DH-1 2008 at 80°F/60%RH inlet air at 0.0 ESP. ⁽²⁾ Height does not include adjustable feet. The width excludes the filter doors and length excludes the duct collars.

FEATURES
Control ⁽³⁾
Front mount only
Air discharge orientation
End of cabinet only
Duct collars
8″
Backdraft damper
No
Filter
1/2″ MERV 8 washable
Refrigerant
R410A
Coil type
Aluminum
Power cord length
8 ft
Hardwire option
No
Discharge air temperature rise
10°F – 30°F
Drain connection⁽⁴⁾
3/4″ MNPT Threaded
⁽³⁾ Built-in automatic control capable to be set up for dehumidification and ventilation or zoning. ⁽⁴⁾ Adapters for threaded connection for plastic hose included.



SPECIFICATIONS
Capacity⁽¹⁾
70ppd
Energy Factor⁽¹⁾
2.1 L/kW-h
Airflow @ varying E.S.P.
(external static pressure – dry coil)
0.0″ w.c.
0.2″ w.c.
0.4″ w.c.
200 CFM
170 CFM
140 CFM
Current Draw⁽¹⁾
5.8 Amps
Noise
53 dBA ducted | 58 dBA unducted
Dimensions: (cabinet only)⁽²⁾
Width
Height
Length
12.5″
12.5″
25.0″
Weight
56 lbs.
Inlet air operating conditions during
-Dehumidification:
50°F – 104°F, 40°F
dew point min.
-Ventilation:
40°F – 140°F,
0% – 99%RH
(non-condensing)
⁽¹⁾ Rated capacity and energy factor test done and current draw measured in accordance with AHAM DH-1 2008 at 80°F/60%RH inlet air at 0.0 ESP. ⁽²⁾ Height does not include adjustable feet. The width excludes the filter doors and length excludes the duct collars.
FEATURES
Control ⁽³⁾
Front mount only
Air discharge orientation
End of cabinet only
Duct collars
8″
Backdraft damper
No
Filter
1/2″ MERV 8 washable
Refrigerant
R410A
Coil type
Aluminum
Power cord length
8 ft
Hardwire option
No
Discharge air temperature rise
10°F – 30°F
Drain connection⁽⁴⁾
3/4″ MNPT Threaded
⁽³⁾ Built-in automatic control capable to be set up for dehumidification and ventilation or zoning. ⁽⁴⁾ Adapters for threaded connection for plastic hose included.
PRINCIPLE OF OPERATION
The Moisture Medic™ 70 pint Dehumidifier is designed to dehumidify the air coming into the unit by passing the incoming air over an evaporator coil to drop the air temperature below the dew point temperature. Moisture condensates is removed from the air and drained out of the unit to a common floor or waste drain. The air is then reheated in the condenser coil and exits the unit.
Dehumidification occurs until the set point is reached, then shuts off until periodic sampling determines a need for operation.
APPLICATION
The Moisture Medic™ 70 pint dehumidifier is the perfect product to dehumidify any crawl space or basement. It also gives you precise management of the humidity in a controlled environment.
The Model HC70 can also be programmed to circulate the air within a crawl space. Circulating the air evens out relative humidity levels and temperature in the space, eliminating variations in the environment.
PRINCIPLE OF OPERATION
The Moisture Medic Model HC70 Dehumidifier is designed to dehumidify the air coming into the unit by passing the incoming air over an evaporator coil to drop the air temperature below the dew point of the air. Moisture is removed from the air and drained out of the unit to a common floor or waste drain. The air is then reheated in the condenser coil and exits the unit.
Dehumidification occurs until the set point is reached, then shuts off until periodic sampling determines a need for operation.
APPLICATION
The Moisture Medic™ 70 pint dehumidifier is the perfect product to dehumidify any crawl space and basement. It also gives you precise management of the humidity in a controlled environment agriculture.
The Model HC70 can also be programmed to circulate the air within a crawl space. Circulating the air evens out relative humidity levels and temperature in the space, eliminating variations in the environment.